When a Fisher & Paykel refrigerator throws Fault Code 3, the control is flagging a temperature sensor (thermistor) problem. That small sensor tells the board how cold the cabinet really is. If the reading is missing, stuck, or wildly off, the fridge can’t regulate cooling, which risks warm food, frozen produce in the fresh zone, or nonstop compressor run time.

What Fault Code 3 Actually Means

In plain English: the control isn’t getting a believable temperature signal. That can be a sensor that aged out, a loose/corroded connector, or a wire that’s rubbed through behind a panel. Sometimes the sensor is fine—but the reading looks “wrong” because airflow is blocked or the compartment is overloaded.

You may notice:

  • Temperatures drifting high/low or swinging during the day
  • Compressor running longer than usual, or short-cycling
  • Ice in places it shouldn’t be, or soft ice cream in the freezer
  • The code returns after a quick unplug/replug reset

Likely Causes (Most to Least Common)

  • Failed thermistor: internal drift, moisture ingress, or physical damage.
  • Harness/connector issues: loose plug, oxidation on pins, or chafed insulation.
  • Airflow problems: blocked return vents, overpacked shelves, or iced-over evaporator confusing the sensor.
  • Environment or installation: unit jammed into a tight cutout with poor ventilation, or room temps outside spec causing unstable readings.

Safe First Steps (Before You Grab Tools)

Unplug the refrigerator or switch off the breaker. Give it 5–10 minutes powered down to clear transient faults, then restore power. If Fault Code 3 returns soon after, proceed with inspection.

Keep doors closed as much as possible while you work to preserve food temps.

DIY Troubleshooting You Can Do Carefully

Start with easy wins. You’re trying to restore a clean, believable temperature signal.

  1. Check the cabinet and airflow
    Make sure product isn’t pressed against back wall vents. Leave space for air to circulate between shelves. If the fridge or freezer is crammed, lighten the load so air can move.
  2. Look for frost or ice sheets
    Pull drawers and inspect rear panels for frost buildup. Heavy frost over the evaporator will throw off sensor readings. A full manual defrost (power off, doors open, towels ready) can clear ice if your model’s defrost cycle fell behind. If frost returns quickly, you’ll want a professional to check defrost components.
  3. Verify installation breathing room
    Confirm the cutout clearances match the spec sheet. Clean the toe-kick and rear area and vacuum the condenser; poor ventilation makes temps wander and can trigger sensor-related faults.
  4. Harness sanity check (basic)
    With power off, remove the necessary interior cover (usually a small panel near the evaporator) just enough to inspect the sensor plug. You’re looking for a loose connector or visible corrosion. Gently reseat once. Don’t pull hard on thin wires.
  5. Control settings
    Make sure the set temperatures are reasonable: 37°F (3°C) for the fridge and 0°F (-18°C) for the freezer are good targets. Some models allow a small “temp offset” in the UI—return it to default if you changed it.

If the code keeps coming back after these steps—or you found damaged wiring—pause here and book service. Repeated fault cycles can stress the compressor and the control board.

When to Call a Pro (and What They’ll Do)

  • Fault Code 3 reappears immediately after a reset and airflow fixes
  • Visible harness damage, corroded connectors, or moisture in the sensor pocket
  • Rapid refrosting after a full manual defrost
  • Temperature never stabilizes within 24 hours

A qualified tech will:

  • Ohm-test the thermistor at known temperatures and compare to spec
  • Inspect and repair the wiring harness and connectors
  • Verify evaporator fan airflow and defrost performance
  • Check control inputs/outputs and update parts with the correct OEM replacements

Practical Fixes You Can Do (If You’re Handy)

Keep it modest—no need to strip the cabinet.

  • Reseat any accessible sensor connector once; ensure it clicks fully home.
  • If you see mild oxidation, a tiny amount of contact cleaner (electronics-safe) on the plug can help—dry thoroughly before reconnecting.
  • Re-route any wire rubbing a sharp edge and secure it in the original clips.
  • After work is done, power up and let the unit stabilize for 12–24 hours before judging results.

Preventing Fault Code 3 in the Future

Good habits go a long way:

  • Don’t block vents: Leave space behind and between items so air can circulate.
  • Keep it clean: Vacuum the condenser and toe-kick every 6–12 months.
  • Mind the load: Avoid overpacking shelves; use crisper drawers as intended to keep sensors reading true cabinet air, not trapped pockets.
  • Stable room temps: Place the fridge away from ovens or direct sun; extreme ambient swings confuse temperature control.
  • Door discipline: Long open times flood the cabinet with warm, humid air—bad for sensors and frost control.

Quick Action Plan

  • Reset power → clear space around vents → confirm set temps
  • Inspect for frost → manual defrost if iced over
  • Reseat accessible sensor connector (power off)
  • If Fault Code 3 returns or wiring/frost issues persist → schedule professional service